Version 3.6.4
- Updates to QIM 03a and QIM 03b
Version 3.6.3
- Updates to report recalculate to minimize RAM usage (when possible)
- Fixed an issue on QIM Reports Export where downloading reports from past quarter are not generating results for all QIMs
Version 3.6.2
- Implemented Report Recalculate for QIM/AIHW reports
- The following reports have been updated by removing hypertension from the list of excluded conditions:
- CV Event Risk Count
- PIP QI CVD Risk Factors
- QIM/AIHW QIM 08 CVD
- Note: Report recalculate is required for these reports to apply the changes
- Updates to PIP QI Essential/Professional
- Introduced new status in Imported Extracts (Click the Import icon on the top right, then on the Imported Extracts tab) called “Included but can't be used in PIP QI” – non-compliant extracts will not be used for PIP QI reporting
- Updates to QIM Report Export (PATCAT View)
- CSV data will be reporting on a quarterly basis, using the most recent data of the quarter only We recommend that you apply a practice filter (PIP QI practices) before performing an export
- Updates to QIM/AIHW 02b – denominator update based on AIHW correction
- Note: Report recalculate is required for this reports to apply the change
- Updates to PIP QI Influenza Immunised Diabetes report where Immunised, Not Recorded and Declined where the sum is not the same as the Target Population
- Note: Report recalculate is required for this reports to apply the change
- Fixed an issue relating to "Maximum call stack size exceeded" error reported by Chrome and IE browsers
Version 3.6
- User Interface refresh
- New functionalities to upload/import PIP QI Aggregated data set (.json file)
- New AIHW reports
- These reports accepts
- PIP QI Aggregates data set (.json file)
- Full extract (MMD/XML) files
- Notes:
- Full extract (MMD/XML) files have priority over .json file (in the event a practice submits both files)
- Only the Practice Filter can be used in these reports
- Licence controlled (at least one)
- PIP QI Essentials
- PIP QI Professionals
- Specific licence code of AIHW report only
- These reports accepts
- PIP QI Report updates (Professional)
- PIP QI Report
- All measures have changed to match CAT4 Summary View
- All existing data will be deleted as the new definitions for the QIMs can’t be applied to the old data
- Requires report recalculate
- PIP QI Diabetes and HbA1c
- Added “Undefined Diabetes” criteria
- Requires report recalculate
- PIP QI Influenza Immunised Over 65
- Added “Declined” criteria
- Requires report recalculate
- PIP QI Influenza Immunised Diabetes
- Added “Declined” criteria
- Added diabetes breakdown of Immunised, Not Recorded and Declined:
- Diabetes Type 1
- Diabetes Type 2
- Undefined Diabetes
- Requires report recalculate
- PIP QI Influenza Immunised COPD
- Added “Declined” criteria
- Requires report recalculate
- PIP QI CVD Risk Factors
- Changed eligible population to:
- (Regular patients >= 45 years and <= 74) and (Regular Indigenous patients >=35 and <45)
- Excludes anyone with existing CVD - taking into account the changes to the CVD grouping condition and it now includes Heart Failure
- Updates to Risk factors
- Requires report recalculate
- Changed eligible population to:
- PIP QI Cervical Screening
- Changed age bracket to “>=25 and <= 74”
- Excludes patients who ‘opted out’ or no longer require cervical screening based on patient record
- Requires report recalculate
- PIP QI Diabetes BP
- All measures have changed
- All blood pressures measures are now broken down by diabetes types:
- Diabetes Type 1
- Diabetes Type 2
- Undefined Diabetes
- All existing data will be deleted
- Requires report recalculate
- PIP QI Report
- Other Updates
- Update Practice Data Quality Benchmark Report
- “Patients >= 18 years with Waist Measurement Recorded” is now displayed correctly
- Cervical Screen section – to match individual report Cervical Screening Last Recorded
- Co morbidities and Medications sections – updates code to align with update CAT4 code
- Requires report recalculate
- Conditions -> Chronic Filter
- Include Heart Failure when CVD filter is used
- Gestational (Yes) to also take into account inactive diagnoses
- Note: Existing data will remain untouched and will only take into effect on new imported extracts after the PATCAT update has been taken
- Virtual Patient Recalculation to re-run (when possible) after it has been interrupted
- Removed “Adjusted” column in all PIP QI Professional reports
- All percentages in reports (table/grid) are now rounded to 2 decimal places
- MyPen Practice Sync Error Mitigations
- Mammogram report can now be used in Prompts
- Updated ranges in the HbA1c report
- Removed “<= 7%” and replaced with
- <6 %
- >= 6% and <= 6.5 %
- > 6.5% and <= 7%
- Requires report recalculate
- Removed “<= 7%” and replaced with
- Show / Hide column saved selections are now additionally scoped to the current view PATCAT, Programs or PIP QI
- CSV download in Practice management screen to include Email
- Metrics for report recalculate
- New report MBS Telehealth and Nurse Practitioner
- Update Practice Data Quality Benchmark Report